Composite Pipe Repair
Industry: Other
Solution: General Pipe Repairs - External Pipe
ID: CPR-11-00117
Project summary:
A coke oven gas (COG) bypass line had a through-wall failure at an elbow. The pipe was left in service for several years, accumulating a large salt deposit and further degrading the pipe wall. The stainless-steel pipe had to be repaired to prevent dangerous gases from escaping. The leak was sealed with wooden wedges, then buried in an epoxy putty. A high-strength, high-temperature carbon fiber reinforcement system was applied to the exterior of the pipe section. This created a structurally independent composite pipe around the badly degraded host pipe.
- Date of installation: 09/22
- End user: Cleveland Cliffs Warren Plant
- Facility/Location: Cleveland, OH
- Applicator: NA Logan
- Products used:
- CF-500 BD
- FRP 200 Saturant
- 110 HT Tack